fix: AWSBedrockLLMService compatibility for newer Claude models
This commit is contained in:
@@ -112,6 +112,12 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
- Fixed an issue where the `RTVIProcessor` was sending duplicate
|
||||
`UserStartedSpeakingFrame` and `UserStoppedSpeakingFrame` messages.
|
||||
|
||||
- Fixed an issue in `AWSBedrockLLMService` where both `temperature` and `top_p`
|
||||
were always sent together, causing conflicts with models like Claude Sonnet 4.5
|
||||
that don't allow both parameters simultaneously. The service now only includes
|
||||
inference parameters that are explicitly set, and `InputParams` defaults have
|
||||
been changed to `None` to rely on AWS Bedrock's built-in model defaults.
|
||||
|
||||
- Fixed an issue in `RivaSegmentedSTTService` where a runtime error occurred due
|
||||
to a mismatch in the `_handle_transcription` method's signature.
|
||||
|
||||
|
||||