Update prompt warning and rename min_end_of_turn_silence_when_confident to min_turn_silence
- Add "beta feature" note to custom prompt warning - Rename min_end_of_turn_silence_when_confident parameter to min_turn_silence across all AssemblyAI code - Update documentation, examples, and test files to use new parameter name
This commit is contained in:
@@ -129,7 +129,7 @@ class AssemblyAIConnectionParams(BaseModel):
|
||||
formatted_finals: Whether to enable transcript formatting. Defaults to True.
|
||||
word_finalization_max_wait_time: Maximum time to wait for word finalization in milliseconds.
|
||||
end_of_turn_confidence_threshold: Confidence threshold for end-of-turn detection.
|
||||
min_end_of_turn_silence_when_confident: Minimum silence duration when confident about end-of-turn.
|
||||
min_turn_silence: Minimum silence duration when confident about end-of-turn.
|
||||
max_turn_silence: Maximum silence duration before forcing end-of-turn.
|
||||
keyterms_prompt: List of key terms to guide transcription. Will be JSON serialized before sending.
|
||||
prompt: Optional text prompt to guide the transcription. Only used when speech_model is "u3-rt-pro".
|
||||
@@ -148,7 +148,7 @@ class AssemblyAIConnectionParams(BaseModel):
|
||||
formatted_finals: bool = True
|
||||
word_finalization_max_wait_time: Optional[int] = None
|
||||
end_of_turn_confidence_threshold: Optional[float] = None
|
||||
min_end_of_turn_silence_when_confident: Optional[int] = None
|
||||
min_turn_silence: Optional[int] = None
|
||||
max_turn_silence: Optional[int] = None
|
||||
keyterms_prompt: Optional[List[str]] = None
|
||||
prompt: Optional[str] = None
|
||||
|
||||
@@ -127,8 +127,8 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
vad_force_turn_endpoint: Controls turn detection mode.
|
||||
When True (Pipecat mode, default): Forces AssemblyAI to return finals ASAP
|
||||
so Pipecat's turn detection (e.g., Smart Turn) decides when the user is done.
|
||||
- min_end_of_turn_silence_when_confident defaults to 100ms (user can override)
|
||||
- max_turn_silence is ALWAYS set equal to min_end_of_turn_silence_when_confident
|
||||
- min_turn_silence defaults to 100ms (user can override)
|
||||
- max_turn_silence is ALWAYS set equal to min_turn_silence
|
||||
- VAD stop sends ForceEndpoint as ceiling
|
||||
- No UserStarted/StoppedSpeakingFrame emitted from STT
|
||||
When False (STT mode, u3-rt-pro only): AssemblyAI's model controls turn endings.
|
||||
@@ -172,10 +172,11 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
# Warn if user sets a custom prompt (recommend testing without one first)
|
||||
if connection_params.prompt is not None:
|
||||
logger.warning(
|
||||
"Custom prompt detected. We recommend testing with no prompt first, as this "
|
||||
"will use our optimized default prompt for voice agents. Bad prompts may lead "
|
||||
"to bad results. If you'd like to create your own prompt, check out our "
|
||||
"prompting guide at: https://www.assemblyai.com/docs/streaming/prompting"
|
||||
"Custom prompt detected. Prompting is a beta feature. We recommend testing "
|
||||
"with no prompt first, as this will use our optimized default prompt for "
|
||||
"voice agents. Bad prompts may lead to bad results. If you'd like to create "
|
||||
"your own prompt, check out our prompting guide at: "
|
||||
"https://www.assemblyai.com/docs/streaming/prompting"
|
||||
)
|
||||
|
||||
# When vad_force_turn_endpoint is enabled, configure connection params
|
||||
@@ -223,15 +224,15 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
when the user is done speaking. VAD stop is the absolute ceiling.
|
||||
|
||||
u3-rt-pro:
|
||||
- min_end_of_turn_silence_when_confident defaults to 100ms (user can override)
|
||||
- max_turn_silence is ALWAYS set equal to min_end_of_turn_silence_when_confident
|
||||
- min_turn_silence defaults to 100ms (user can override)
|
||||
- max_turn_silence is ALWAYS set equal to min_turn_silence
|
||||
to avoid double turn detection (AssemblyAI + Pipecat both analyzing)
|
||||
- If user sets max_turn_silence, it's ignored with a warning
|
||||
- end_of_turn_confidence_threshold: not set (API default)
|
||||
|
||||
universal-streaming-*:
|
||||
- end_of_turn_confidence_threshold=0.0 (disable semantic turn detection)
|
||||
- min_end_of_turn_silence_when_confident=160
|
||||
- min_turn_silence=160
|
||||
- max_turn_silence: not set (API default)
|
||||
|
||||
Args:
|
||||
@@ -244,8 +245,8 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
updates = {}
|
||||
|
||||
if is_u3_pro:
|
||||
# u3-rt-pro: Synchronize max_turn_silence with min_end_of_turn_silence_when_confident
|
||||
min_silence = connection_params.min_end_of_turn_silence_when_confident
|
||||
# u3-rt-pro: Synchronize max_turn_silence with min_turn_silence
|
||||
min_silence = connection_params.min_turn_silence
|
||||
if min_silence is None:
|
||||
min_silence = 100
|
||||
|
||||
@@ -254,20 +255,20 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
logger.warning(
|
||||
f"Your max_turn_silence value ({connection_params.max_turn_silence}ms) will be "
|
||||
f"OVERRIDDEN in Pipecat mode (vad_force_turn_endpoint=True). It will be set to "
|
||||
f"{min_silence}ms (matching min_end_of_turn_silence_when_confident) and SENT to "
|
||||
f"{min_silence}ms (matching min_turn_silence) and SENT to "
|
||||
f"AssemblyAI to avoid double turn detection. To use your max_turn_silence as-is, "
|
||||
f"switch to STT mode (vad_force_turn_endpoint=False)."
|
||||
)
|
||||
|
||||
updates = {
|
||||
"min_end_of_turn_silence_when_confident": min_silence,
|
||||
"min_turn_silence": min_silence,
|
||||
"max_turn_silence": min_silence,
|
||||
}
|
||||
else:
|
||||
# universal-streaming: Different configuration (works differently)
|
||||
updates = {
|
||||
"end_of_turn_confidence_threshold": 0.0,
|
||||
"min_end_of_turn_silence_when_confident": 160,
|
||||
"min_turn_silence": 160,
|
||||
}
|
||||
|
||||
# Apply updates if any
|
||||
@@ -292,7 +293,7 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
- keyterms_prompt: List of terms to boost (can be empty array to clear)
|
||||
- prompt: Custom prompt text (u3-rt-pro only)
|
||||
- max_turn_silence: Maximum silence before forcing turn end
|
||||
- min_end_of_turn_silence_when_confident: Silence before EOT check
|
||||
- min_turn_silence: Silence before EOT check
|
||||
|
||||
Args:
|
||||
delta: A :class:`STTSettings` (or ``AssemblyAISTTSettings``) delta.
|
||||
@@ -351,18 +352,18 @@ class AssemblyAISTTService(WebsocketSTTService):
|
||||
f"Updating max_turn_silence to: {conn_params.max_turn_silence}ms"
|
||||
)
|
||||
|
||||
if hasattr(conn_params, "min_end_of_turn_silence_when_confident"):
|
||||
if hasattr(conn_params, "min_turn_silence"):
|
||||
if (
|
||||
old_conn_params is None
|
||||
or conn_params.min_end_of_turn_silence_when_confident
|
||||
!= old_conn_params.min_end_of_turn_silence_when_confident
|
||||
or conn_params.min_turn_silence
|
||||
!= old_conn_params.min_turn_silence
|
||||
):
|
||||
if conn_params.min_end_of_turn_silence_when_confident is not None:
|
||||
update_config["min_end_of_turn_silence_when_confident"] = (
|
||||
conn_params.min_end_of_turn_silence_when_confident
|
||||
if conn_params.min_turn_silence is not None:
|
||||
update_config["min_turn_silence"] = (
|
||||
conn_params.min_turn_silence
|
||||
)
|
||||
logger.info(
|
||||
f"Updating min_end_of_turn_silence_when_confident to: {conn_params.min_end_of_turn_silence_when_confident}ms"
|
||||
f"Updating min_turn_silence to: {conn_params.min_turn_silence}ms"
|
||||
)
|
||||
|
||||
# Send update if we have parameters to update
|
||||
|
||||
Reference in New Issue